File Revision Date: ---- -------- ----- October 30, 2026 Data Set Description: ---- --- ------------ PI: Patrick Cullis Instrument: ECC Ozonesondes Sites: Boulder, CO USA 39.949°N, 105.197°W, 1743 masl Hilo, HI USA 19.717°N, 155.049°W, 10 masl South Pole, ANTARCTICA 45.038°S, 169.683°E, 370 masl Pago Pago, AMERICAN SAMOA 14.331°S, 170.714°W, 5 masl Measurement Quantities: Ozone partial pressure, Ozone mixing ratio, Pressure, Temperature, Relative humidity, Geopotential height, GPS Altitude, Latitude and Longitude of payload (for most soundings since 2009), Horizontal wind speed and direction (for most soundings since 2009). Contact Information: ------- ------------ Name: Patrick Cullis Address: NOAA Earth System Research Laboratory, Global Monitoring Laboratory 325 Broadway R/GML1 Boulder, Colorado 80305 U.S.A. Phone: (303)497-6674 Email: Patrick.Cullis@noaa.gov DOI: ---- Not at this time. Data License: ---- -------- CC0 Reference Articles: --------- --------- Johnson, B. J., Oltmans, S. J., Vömel, H., Smit, H. G. J., Deshler, T., and Kroger, C., Electrochemical concentration cell (ECC) ozonesonde pump efficiency measurements and tests on the sensitivity to ozone of buffered and unbuffered ECC sensor cathode solutions, J. Geophys. Res., 107( D19), 4393, doi:10.1029/2001JD000557, 2002. Sterling, CW, BJ Johnson, SJ Oltmans, HGJ Smit, AF Jordan, PD Cullis, EG Hall, AM Thompson and JC Witte, 2018: Homogenizing and estimating the uncertainty in NOAAs long-term vertical ozone profile records measured with the electrochemical concentration cell ozonesonde Atmos. Meas. Tech. , COPERNICUS GESELLSCHAFT MBH, 11 ( 6 ) , 3661-3687, doi: 10.5194/amt-11-3661-2018, issn: 1867-1381, ids: GK5WG, 26-Jun 2018 McPeters, R.D., Hofmann, D.J., Clark, M., Flynn, L., Froidevaux, L., Gross, M., Johnson, B.J. , Koenig, G., Liu, X., McDermid, S., McGee, T., Murcray, F., Newchurch, M.J., Oltmans, S., Parrish, A., Schnell, R., Singh, U., Tsou, J.J., Walsh, T., and Zawodny, J.M., Results from the 1995 stratospheric ozone profile intercomparison at Mauna Loa. J Geophys. Res. 104, 30,505-30,514, 1999. Oltmans, S.J., A.S. Lefohn, H.E. Scheel, J.M. Harris, H. Levy II, I.E. Galbally, E.G. Brunke, C.P. Meyer, J.A. Lathrop, B.J. Johnson, D.S. Shadwick, E. Cuevas, F.J. Schmidlin, D.W. Tarasick, H. Claude, J.B. Kerr, O. Uchino, V. Mohnen, Trends of Ozone in the Troposphere, Geophys. Res. Lett., 25, 139-142, 1998. Hofmann, D.J., S.J. Oltmans, J.M. Harris, B.J. Johnson, J.A. Lathrop, Ten Years of Ozonesonde Measurements at the South Pole: Implications for Recovery of Springtime Antarctic Ozone, J. Geophys. Res., 102, 8931-8943, 1997. Johnson, B.J., S.J. Oltmans, D. J. Hofmann, J.A. Lathrop, Evaluation of ECC Ozonesonde Performance from Recent Field and Laboratory Intercomparisons, Proc. Quad. Ozone Symp., L'Aquila, Italy, 1996. Hofmann, D.J., Oltmans, S.J., Harris, J.M., Komhyr, W.D., Lathrop, L.A., Defoor, T., and Kuniyuki, D., Ozonesonde measurements at Hilo, Hawaii following the eruption of Pinatubo, Geophys. Res. Lett. 20, 1555-1558, 1993. Smit, H. G. J., Thompson, A. M., and the ASOPOS 2.0 Panel: Ozonesonde Measurement Principles and Best Operational Practices, WMO Global Atmosphere Watch Report Series, No. 268, World Meteorological Organization, Geneva, https://library.wmo.int/idurl/4/57720, 2021 Instrument Description: ---------- ------------ The ECC Ozonesonde (Electrochemical Concentration Cell Ozonesonde) is a lightweight, balloon-borne instrument mated to a meteorological radiosonde and flown to 30+ km while transmitting data back to a ground station. The heart of the ozonesonde is an electochemical concentration cell (ECC) that senses ozone as it reacts with a dilute solution of potassium iodide to produce an electrical current proportional to the ozone concentration of the air. ECC's connected to Vaisala RS-80-15 type radiosondes using En-Sci V2C interface board. ECC's connected to Intermet iMet-1 type radiosondes using En-Sci V7 interface board. ECC's connected to Intermet iMet-4-RSB type radiosondes using En-Sci V7 interface board. TMAX interface board used for all 5A, 6A, and 1Z sondes Analog data system used for most 4A sondes Vaisala radiosonde receiving station was an ICOM receiver and 300 baud modem (V2C) or a KAM Plus programmable modem (TMAX) into the NOAA/CMDL data acquisition program: Strato version 7.2 Starting in 2009 with Intermet iMet-1 radiosondes, data is received with SkySonde software and ICOM receiver, or software modem built in to SkySonde. Boulder: Project start date: March 12, 1979 Pre-project period: April 27, 1967 to July 20, 1971 Start digital data acquisition: June 11, 1991 Switched from 1% KI buffered cathode solution to 2% KI unbuffered: August 21, 1997. Switched from 2% KI unbuffered cathode solution to 1% 1/10th buffered: August-November, 2005. Used Science Pump 4A, 5A, 6A and ENSCI 1Z, 2Z models. Hilo: Project start date: September 21, 1982 Start digital data acquisition: July 18, 1991 Switched from 1% KI buffered cathode solution to 2% KI unbuffered: April 15, 1998. Switched from 2% KI unbuffered cathode solution to 1% 1/10th buffered: December 20, 2005. Used Science Pump 4A, 5A, 6A and ENSCI 1Z, 2Z models. S.Pole: Project start date: January 20, 1986 Pre-project period: January 17, 1967 to October 14, 1971 Start digital data acquisition for ozonesondes: November 3, 1990 Switched from 1% KI buffered cathode solution to 2% KI unbuffered: March 4, 1998. Switched from 2% KI unbuffered cathode solution to 1% 1/10th buffered: November 15, 2004. Used Science Pump 4A, 5A, 6A and ENSCI 1Z, 2Z models. Samoa: Project start date: August 8, 1995 Pre-project period: April 1, 1986 to January 23, 1990 Start digital data acquisition: August 8, 1995 Switched from 1% KI buffered cathode solution to 2% KI unbuffered: April 17, 1998 Switched from 2% KI unbuffered cathode solution to 1% 1/10th buffered: October 22, 2005 Used Science Pump 4A, 6A and ENSCI 1Z, 2Z models. Algorithm Description: --------- ------------ Ozone is calculated as a partial pressure. PTU data from the sonde is not used directly in the calculation except in the pump correction. PPOZ(nb) = 0.004307 * i * Temperature * t *PCF where: i is the current from the sensor - background in uA. t is the time in seconds to pump 100 CCs of air through the pump. Temperature is the pump temperature (K). PCF is the pump correction factor to account for loss in pump efficiency at lower pressures. Background current is assumed to be constant. The average pump correction factor (pcf) is calculated from an average of ozonesonde flow rates measured at NOAA/CMDL using an oil bubble flow meter inside an environmental chamber. Pressure (pcf) 5.0 1.255 7.0 1.191 10.0 1.137 20.0 1.074 30.0 1.056 50.0 1.041 100.0 1.025 300.0 1.007 1000 1.000 Expected Precision/Accuracy of Instrument: -------- ------------------ -- ----------- Ozonesonde: hPa Accuracy Precision Resolution 1000 +/- 5% +/- 4% 0.3km 100 +/- 5% +/- 3% 0.3km 10 +/- 5% +/- 3% 0.4km 4 +/- 10% +/- 10% 0.4km Vaisala RS80 Radiosonde Measurements of Pressure, Temperature and Relative Humidity Pressure: Resolution 0.1 hPa Accuracy +/- 0.5 hPa Temperature: Resolution 0.1 K Accuracy +/- 0.2 K Relative Humidity: Resolution 1% RH Accuracy +/- 2% RH ——--------------- InterMet iMet-1-RSB Measurements of Pressure, Temperature and Relative Humidity (PTU) Pressure: Resolution 0.01 hPa Accuracy +/- 0.5 hPa Temperature: Resolution 0.01 K Accuracy +/- 0.2 K Relative Humidity: Resolution 0.1% RH Accuracy +/- 5 % RH Geopotential Height: Calculated using radiosonde PTU measurements. Errors due to uncertainty in the PTU values. Instrument History: ---------- -------- ECC Ozonesondes: Manufacturer: Model # Time Period Used Ozonesonde Design and Changes Science Pump 1A 1967-1981 Rectangular pump/square Teflon sensor cell Thermistor at base of ozonesonde body Analog data acquisition Science Pump 3A 1979-1982 Commutator moved to electronics board Science Pump 4A 1982-1991 Cylindrical piston pump Science Pump 5A 1990-1996 Digital data acquisition Pump Temperature thermistor epoxied to corner of pump block Science Pump 6A 1996-present Pump temperature thermistor inside of pump block EN-SCI 1Z 1994-2000 Different manufacturer but the same design as Science Pump 6A EN-SCI 2Z 1997-present Circular molded plastic sensor cell Boulder: 1A: April 1967 - June 1981 3A: September 1981 - June 1982 4A: June 1982 - December 1989 5A: June 1991 - October 1994 1Z: March 1994 - January 1999 6A: January 1997 - Present (Most before November 2005) 2Z: January 1998 - Present Hilo 4A: September 1982 - July 1991 5A: July 1991 - December 1994 1Z: April 1994 - March 1998 6A: January 1997 - November 1998 2Z: July 1998 - Present South.Pole 1A: January 1967 - October 1971 4A: January 1986 - November 1990 5A: November 1990 - June 1994 1Z: July 1994 - December 1997 6A: December 1997 - Present (Most before September 2001) 2Z: January 1999 - Present Samoa 4A: April 1, 1986 - January 23, 1990 1Z: August 8, 1995 - January 23, 1997 6A: January 30, 1997 - May 4, 2007 2Z: January 27, 2006 - Present Solution Recipe Changes (Specific Dates detailed in i: 1967-1998 - 1% KI, 1.0x buffer 1998-2005 - 2% KI, no buffer 2005-present 1% KI, 0.1x buffer Radiosonde changes: 1967-1991 - VIZ "A" radiosondes and analog data recording. Feb 1991-2009 - Vaisala RS-80 radiosondes May 2009-2020/2022 Intermet iMet-1 radiosondes 2020/2022-present Intermet iMet-4 radiosondes Boulder: Switched from 1% KI buffered cathode solution to 2% KI unbuffered: August 21, 1997. Switched from 2% KI unbuffered cathode solution to 1% KI 1/10th buffered: August-November, 2005. Hilo: Switched from 1% KI buffered cathode solution to 2% KI unbuffered: April 15, 1998. Switched from 2% KI unbuffered cathode solution to 1% KI 1/10th buffered: December 20, 2005. S.Pole: Switched from 1% KI buffered cathode solution to 2% KI unbuffered: March 4, 1998. Switched from 2% KI unbuffered cathode solution to 1% KI 1/10th buffered: November 15, 2004. Samoa: Switched from 1% KI buffered cathode solution to 2% KI unbuffered: April 17, 1998. Switched from 2% KI unbuffered cathode solution to 1% KI 1/10th buffered: October 22, 2005. GEOMS-HDF data have been processed according to the homogenization guidelines described in Smit et al. [2021], with keyword “WMOGAW268”.