ANCELLET G. O3SONDE OHP OZONE 11-APR-1997 22:38:3311-APR-1997 22:55:559999 122 2160 ANCELLET, Gerard and GODIN-BEEKMANN, Sophie LATMOS, CNRS, FRANCE Ozonesonde ECC NDACC 1 1 1997 04 11 2021 12 20 0 30 Pressure at observation (hPa) Station name 13 1 1 1 1 1 1 1 1 1 1 1 1 1 99999 99999 999.9 999 999.9 99.9 999 999.9 99.9 9999 9999 9999 9999 Time after launch (s) Geopotential height (gpm) Temperature (C) Relative humidity (%) Temperature inside styrofoam box (C) Ozone partial pressure (mPa) Horizontal wind direction (degrees) Horizontal wind speed (m/s) ECC current (micro A) Pump temperature (K) Relative error on pump temperature (%) Corrected Ozone partial pressure (mPa) Error on Ozone partial pressure (mPa) 60 18 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 9999 99.999 999.99 999.99 999.9 99.9 99999.9 99999.9 99999.9 99999.9 9.9999 9.9999 999999 999999 999999 9.999 9.999 9.999 9.9 99.9 99.99 99.99 9.999 9.999 99.9 99.99 9999.9 9.9999 99.999 99 999.9 999 999 9.999 99.9 999 99.9 999.9 99999.9 99999.9 9.999 999.9 60 80 23 40 20 13 2 7 20 20 40 10 20 20 20 20 40 40 zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzz zz zzzzzzz zzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz zzzzzzzzzz zzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz Number of pressure levels Launch time (Decimal UT hours from 0 hours on day given by DATE) Longitude of station (E is positive) (decimal degrees) Latitude of station (N is positive) (decimal degrees) Wind speed at ground at launch (m/s) Temperature at ground at launch (C) Free lift for rubber balloon (g) Dummy weight for plastic balloon (g) Balloon volume for plastic balloon (m^3) Balloon weight for rubber balloon (g) Interface parameter U1 Interface parameter U2 Interface parameter R1 Interface parameter R2 Interface parameter R3 Interface parameter K0 Interface parameter K1 Interface parameter K2 Amount of cathode solution (cm3) Concentration of cathode solution (g/l) Sensor air flow rate (calibrator and ozonesonde pumps operating)(s) Sensor air flow rate (ozonesonde pump only operating)(s) Background sensor current before cell is exposed to ozone (microamperes) Background sensor current in the end of the pre-flight calibration(microamperes) Time the sonde was run for surface ozone (min) Surface ozone measured with the sonde prior to launch(mPa) Background surface pressure (hPa) Pressure correction at ground Temperature correction at ground Humidity correction at ground Total ozone from sondeprofile (COL1) Total ozone measured with Dobson/Brewer (daily mean) (COL2A) Total ozone measured with Dobson/Brewer (best value)(COL2B) Correction factor (COL2A/COL1 or COL2B/COL1) (NOT APPLIED TO DATA) Temperature in laboratory during sonde flow rate calibration (C) Relative humidity in laboratory during sonde flow rate calibration (%) Temperature at sonde inlet tube prior to launch (C) Residual ozone with monthly climatology above burst level (DU) uncorrected pump flow rate (s) uncorrected background current (micro A) uncorrected correction factor uncorrected residual ozone (DU) Ground equipment Pump correction table Background current correction method Vertical averaging/smoothing method Box temperature measured from |In the box | inside the pump| Name of raw data file Lifting gas Balloon material (RUBBER or PLASTIC) Balloon brand (e.g. TOTEX, RAVEN) Balloon type, (e.g. TX1200, CL0019) Reason for discontinuation Weather condition at launch Balloon pretreatment Serial number of ECC Serial number of interface card Serial number of RS-80 Reserved Reserved 0 4 The Haute-Provence Observatory ozonesonde program uses 5A series ECC sondes manufactured by the SPC and Vaisala RS80-18H radiosondes coupled by a TMAX (H-MOS type) interface board. See metafile for more details. observatoire de haute-provence 46 22.642 5.71 43.94 999.9 12.0 410.0 99999.9 99999.9 1200.0 9.9999 9.9999 999999 999999 999999 9.999 9.999 9.999 3.0 10.0 99.99 25.91 9.999 0.02 99.9 99.99 934.0 9.9999 99.999 99 999.9 999 315 9.999 99.9 999 99.9 999.9 25.66 0.02 9.999 999.9 Home made (jan.1991/jul.2007), MODEM since jul.2007 Komhyr 1986 table for SPC 1991-1997 and Komhyr 1995 table for ENSCI since 1997 Constant IB2 correction zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzz He RUBBER KKS or TOTEX TX1200 zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz zzzzzzzzzz none Z zzzzzzzzzzzzzzzzzzzz RSH015 zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz 933.80 0 673 12.7 27 32.9 5.85 999 999.9 1.78 308.27 0.29 5.81 0.35 923.50 95 766 12.9 26 32.6 5.97 999 999.9 1.79 308.01 0.29 5.84 0.36 913.00 129 862 12.8 26 32.6 6.07 999 999.9 1.88 308.05 0.29 6.14 0.37 903.90 169 946 12.4 27 32.6 6.12 999 999.9 1.83 308.08 0.29 5.97 0.36 894.10 196 1037 12.3 26 32.6 6.00 999 999.9 1.77 308.11 0.29 5.77 0.35 883.10 223 1141 12.3 23 32.6 5.87 999 999.9 1.74 308.15 0.29 5.68 0.35 871.70 244 1249 12.1 21 32.6 5.74 999 999.9 1.67 308.2 0.3 5.45 0.34 859.60 264 1366 12.0 19 32.6 5.57 999 999.9 1.61 308.24 0.3 5.25 0.33 846.70 284 1493 11.9 18 32.6 5.37 999 999.9 1.54 308.29 0.3 5.02 0.32 836.60 298 1593 11.5 18 32.6 5.26 999 999.9 1.52 308.33 0.3 4.95 0.31 828.00 311 1678 10.9 17 32.6 5.19 999 999.9 1.53 308.36 0.3 4.99 0.32 819.60 325 1763 10.5 17 32.6 5.13 999 999.9 1.47 308.4 0.3 4.79 0.31 810.10 345 1860 9.6 17 32.6 4.99 999 999.9 1.44 308.44 0.3 4.69 0.3 799.00 365 1973 8.9 16 32.6 4.89 999 999.9 1.45 308.48 0.3 4.72 0.3 788.50 379 2083 8.6 14 32.6 4.80 999 999.9 1.37 308.52 0.31 4.46 0.29 775.20 392 2223 8.4 13 32.6 4.67 999 999.9 1.35 308.58 0.31 4.4 0.29 760.90 406 2376 7.8 12 32.6 4.59 999 999.9 1.29 308.64 0.31 4.2 0.28 748.20 419 2514 7.1 11 32.6 4.44 999 999.9 1.28 308.69 0.31 4.17 0.28 737.20 433 2635 6.1 11 32.6 4.32 999 999.9 1.25 308.74 0.31 4.07 0.28 727.50 446 2742 5.3 10 32.6 4.27 999 999.9 1.26 308.79 0.31 4.1 0.28 718.60 460 2842 4.8 10 32.6 4.24 999 999.9 1.26 308.83 0.32 4.1 0.28 708.10 480 2962 4.2 9 32.6 4.22 999 999.9 1.26 308.87 0.32 4.1 0.28 699.60 501 3060 3.7 8 32.2 4.12 999 999.9 1.20 308.51 0.32 3.9 0.27 691.10 521 3159 3.0 8 32.6 4.07 999 999.9 1.23 308.95 0.32 4.0 0.27 682.60 541 3258 2.4 7 32.6 4.09 999 999.9 1.24 308.99 0.32 4.04 0.27 675.30 561 3345 1.6 7 32.6 4.15 999 999.9 1.26 309.03 0.32 4.1 0.28 667.70 582 3435 0.8 7 32.2 4.19 999 999.9 1.26 308.67 0.32 4.1 0.28 660.30 602 3525 0.1 6 32.6 4.28 999 999.9 1.30 309.1 0.33 4.24 0.28 651.90 629 3627 -0.7 5 32.2 4.39 999 999.9 1.33 308.74 0.33 4.33 0.29 645.10 649 3710 -1.4 4 32.2 4.44 999 999.9 1.34 308.78 0.33 4.37 0.29 637.30 670 3807 -1.9 3 32.2 4.45 999 999.9 1.33 308.82 0.33 4.33 0.29 629.10 690 3909 -2.6 4 32.2 4.45 999 999.9 1.31 308.86 0.33 4.27 0.28 620.80 710 4014 -3.5 3 32.2 4.43 999 999.9 1.32 308.9 0.33 4.3 0.29 614.10 724 4099 -4.1 3 32.2 4.39 999 999.9 1.29 308.94 0.33 4.2 0.28 605.50 744 4210 -5.2 3 32.2 4.33 999 999.9 1.28 308.98 0.34 4.17 0.28 598.20 758 4304 -5.9 3 32.2 4.29 999 999.9 1.27 309.02 0.34 4.14 0.28 589.60 778 4417 -7.1 5 32.2 4.21 999 999.9 1.24 309.07 0.34 4.04 0.27 581.20 798 4528 -8.2 6 32.2 4.14 999 999.9 1.22 309.12 0.34 3.97 0.27 573.90 819 4626 -9.2 6 32.2 4.09 999 999.9 1.20 309.16 0.34 3.91 0.27 567.70 839 4709 -9.9 6 32.2 4.04 999 999.9 1.18 309.19 0.34 3.84 0.27 561.50 859 4794 -10.5 8 32.2 3.88 999 999.9 1.07 309.23 0.34 3.48 0.25 554.90 886 4884 -11.1 7 32.2 3.61 999 999.9 1.05 309.27 0.35 3.41 0.25 549.30 920 4962 -11.8 6 32.2 3.57 999 999.9 1.07 309.3 0.35 3.48 0.25 543.30 961 5046 -12.5 5 31.8 3.60 999 999.9 1.05 308.94 0.35 3.41 0.25 537.50 1002 5128 -12.7 6 31.8 3.46 999 999.9 0.97 308.97 0.35 3.14 0.24 532.10 1042 5205 -13.0 7 31.4 3.21 999 999.9 0.94 308.61 0.35 3.04 0.23