NASA - National Aeronautics and Space Administration
FIND IT @ NASA
HOME MISSIONS DATA TOOLS ABOUT US
NASA Tropospheric Chemistry Integrated Data Ceneter
Overview and Other DocuemntsConcurrent MissionsParticipantsInstruments and MeasurementsImplementationData ProductsPhoto GalleryOutreachWorkshopsPublications and Manuscripts

 

Chemical Ionization Mass Spectrometry-Based Measurements of HO2 and RO2 During TRACE-P

Christopher A. Cantrell, NCAR Boulder, CO

 

The peroxy radical CIMS (PerCIMS) is generally based on the selected ion CIMS measurement of hydroxyl radicals. In the PerCIMS method, reagent gases NO and SO2 are added to ambient air, leading to the conversion of ambient peroxy radicals (RO2 and/or HO2) to gas-phase sulfuric acid.The H2SO4 product is detected first by ionization through a proton transfer reaction with , followed by introduction into a vacuum system with ion optics, differential pumping, quadrupole mass filter and channel electron multiplier for ion counting. 

The PerCIMS instrument is unique in that we have developed methods to yield measurement of total peroxy radical levels ([HO2] + [RO2]), and measurement of [HO2] by adjusting the reagent gas concentrations in the inlet region.  These two measurements yield additional information about atmospheric processing of hydrocarbons and the branched chain reactions that lead to partitioning of peroxy radicals between the hydro- and organic-peroxy radical forms.

Calibration of the instrument is accomplished through photolysis of water vapor using 184.9 nm radiation from a low-pressure mercury lamp.  Radical concentrations in the range of ambient concentrations (and higher) are easily generated by adjusting the lamp distance, slit width and water vapor concentration. The lamp flux is determined through N2O actinometry.  Relative sensitivity of various peroxy radicals are measured using the photolysis of Cl2 to yield chlorine atoms that react with hydrogen and various hydrocarbon precursors.  Sample data from the TOPSE aircraft campaign are shown in the figure.

  These measurements are accomplished with an estimated ±30% accuracy, detection limit of 1 x 107 radicals-cm-3 in 15 seconds, and typical 2s precision of 10% at 1 x 108 radicals-cm-3.  Lower detection limits with better precision are possible with appropriate averaging.

Cantrell image


 

NASA - National Aeronautics and Space
 Administration
Curator: Ali Aknan
NASA Official: Dr. Gao Chen

+ Freedom of Information Act
+ Budgets, Strategic Plans and Accountability Reports
+ The President's Management Agenda
+ Inspector General Hotline
+ Equal Employment Opportunity Data Posted Pursuant to the No Fear Act
+ Information-Dissemination Priorities and Inventories
+ Privacy Policy and Important Notices
+ USA.gov
+ ExpectMore.gov
+ Multimedia Browser Plug-ins
+ Comments or Questions?